one.2.2 Warning Labels Warning Labels Meaning Remember to carefully look at this guide in advance of use unit. The next labels undoubtedly are a. Never spot the gadget on the sloped area. Or else the offered once the process product may well slide, causing particular injuries or perhaps the machine operates Together with the mobile malfunction.

Cookie penting untuk memfungsikan situs dengan semestinya. Untuk meningkatkan pengalaman Anda, kami menggunakan cookie untuk mengingat depth login Anda dan menyediakan login aman, mengumpulkan statistik untuk mengoptimalkan fungsionalitas situs, dan menyediakan konten yang disesuaikan dengan minat Anda.

three. Click on the upper icon in the display (prompts “Update” if you set the cursor on it), the update step is carried out, if fails, you should ship to R&D Heart. Figure six-one Main Check Maintenance Screen four. Following update is thriving, restart the equipment right after power off to make the data efficient. HDD Partition ... Site ninety one structured report linked information file and DICOM viewing software package Report report template obd.bin OBD information file Variation.txt Model file Remark Comment file AnatomyImage Anatomical illustrations or photos Measurement Measurement library Doppler application and linked boot configuration principal file and plug-ins, distant desktop server Multilanguage string file exe videoplay.

Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.

Slice off cable ties connecting the leading unit over the Show by diagonal slicing pliers, then pull out the corresponding cable plugs.

Mindray’s new generation of black & white ultrasound process, DP-fifty Skilled, is provided with advanced imaging technologies allowing for deeper penetration and faster image acquisition with increased resolution.

The chapter provides the tactic to verify main perform and efficiency of product or service. This is often only employed for reference, not preventive execution. Operate checking and tests of this component shall be performed by Mindray company engineers and also the consumer together. Webpage sixty six: Typical Exam

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi element mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Permits utilization of many scanned angles to type a single image, causing Improved contrast resolution and improved visualization

five.two.three Geometric positioning precision Longitudinal geometric positioning accuracy  Take a look at Stage: Do changes as how in testing the maximum depth. Report the space by 20mm Each individual segment within the longitudinal targets line utilizing the measurement caliper; Decide on the worth with the greatest error (to 20mm), estimate the precision utilizing the formulation underneath The measurement caliper must be positioned at the upper edge of the goal, Notice:... Page 79 Transverse geometric positioning accuracy  Check Phase: Deal with the scan area from the phantom with water or couple gel, Carefully contact the probe Along with the scan area Adjust the depth, creating the transverse targets for being displayed inside the picture. Modify the focus point to be posited beside the transverse targets (the standard is not clear) Adjust parameters like gain, TGC, making Every transverse targets to become Evidently shown. Webpage eighty 5.five.two.4 Blackout Region Check Step: Address the scan floor on the phantom with water or pair gel, Carefully Call the probe Along with the scan floor Alter the depth in a reduce value, and set the main target at the closest location to the scan area. Decrease the worth of parameters like AP, Obtain right up until the history sound just is often observed. Website page 81: Computer software Up grade And Servicing

Right after productive connection, the newly additional network printer title is going to be shown in the printer driver list. NOTE: In advance of join the community printer, ensure that the ultrasound procedure as well as printer are in precisely the same community area, as well as the network is Doing the job Commonly. The IP tackle and also the server title should be valid, e.g. Site 47 DICOM Environment  Enter the AE Title on the ultrasound system, port and PDU Dp50rb login in accordance with the precise predicament, then click on [OK] to exit the screen.

.. Site 161 The indicator to the printer Errors manifest if the adapter turns orange, along with the printing printer adapter operates. Disconnect and link the fails. electric power adapter, electricity to the printer adapter once again, and verify if the printing is usual right after 1 moment. Web page 163: Electrical Security Inspection

Cookies are very important to the appropriate functioning of a internet site. To improve your practical experience, we use cookies to remember log-in specifics and provide protected log-in, obtain statistics to optimize site operation, and produce written content personalized for your passions.

Just after changing the CPU module, key file need to be created once again according to the new MAC address and prepared into HDD of the machine. Or else, the configuration operate of the merchandise is going to be lost. Right after getting rid of the CPU module, Take out panhead screws with washers (12 M3X6) set on the key unit box, you usually takes off the board. Website page 118 Figure 8-29 Disassemble the User interface Assembly (one) Maintain the upper edge of user interface assembly, and open up the user interface. Determine eight-30 Disassemble the User interface Assembly (2) Immediately after taking away 1 countersunk head self-tapping screw PT3X10 fixed around the control panel and get out the plug with the keyboard and the primary unit connecting cables, you may clear away the user interface assembly.

Be aware: Make certain that you could potentially pull out and push to the IO board sockets vertically when pulling out and assembling the IO board assembly about the posture of the deal with. Clear away panhead screws with washers M3X6 (four) accustomed to secure the IO board, and after that you can consider out the IO board. Webpage 116 Clear away panhead screws with washers (two M3X6) which can be preset on the main unit, take out the upper baffle and afterwards pull out two cables connecting the main board to the facility module assembly.

Leave a Reply

Your email address will not be published. Required fields are marked *